Marine PINPOINT pH Monitor
** |
PINPOINT pH Monitor™
The PINPOINT pH Monitor is in use by thousands
of customers worldwide. This affordable unit remains the only full-time
pH monitor with .01 resolution. The PINPOINT pH Monitor
requires only a 9-volt battery and is sold complete with probe and calibration
fluids. The electrode is also available separately and fits any meter
or monitor. Comes complete with meter, probe and all calibration fluids.
- Given
proper care, the PINPOINT pH Monitor should last
a lifetime.
- PINPOINT
pH Probe comes with a 10 foot high supression cable and a BNC
connector.
- Powered
by a standard 9-volt battery (not included).
- Optional
AC Adaptor Kit, replacement pH probe, and additional calibration fluid
available.
American
Marine is proud to introduce PINPOINT , the only
truly accurate and affordable continuous pH monitoring system. Powered
by a 9-volt battery (not included). PINPOINT will continuously
monitor and display pH for months before battery replacement is visually
indicated on the display as "LOBAT".
NOTE: The pH monitor unit is NOT waterproof and must be operated
on a dry surface. Liquid contact on the printed circuit board will cause
corrosion and void warranty.
Set-up
Unwrap the protective plastic packaging from both the monitor and the
blue epoxy probe. CAREFULLY remove the plastic storage cap installed
over the end of the probe. A small amount of storage fluid will be expelled.
SAVE the plastic storage cap for future use. Rinse the end of the probe
briefly under the lukewarm tapwater. Remove the battery cover on the
back of the monitor and install a 9-volt battery or the PINPOINT
AC Adapter Kit. Attach the BNC connector from the wire on the probe
to the BNC input of the monitor. Turn the connector 1/4 turn clockwise
to lock the connector.
Activate the unit by setting the power switch to the ON position. Use
the pop-up stand on back and place meter on any flat, dry surface.
Your PINPOINT pH Monitor is now ready for calibration.
Two Point Calibration (Use only high-quality, fresh calibration
fluids)
- For
maximum performance the PINPOINT pH Monitor should
be calibrated immediately. Proper calibration requires the use of
2 different fluids; one of which must be #7.00. Any combination
of either (#7.00 and #4.00) or (#7.00 and #10.00) will give excellent
results.
- All
calibration fluids should be room temperature 68°- 86°F
(20°- 30°C)
- With
monitor turned "ON", place the end of the pH probe into
calibration fluid #7.00 Using a miniature screwdriver, turn screw
labeled #7 on the front panel of the meter (see diagram) until display
reaches 7.00 exactly.
- Rinse
probe in room temperature tapwater.
- Place
pH probe into calibration fluid #4.00 (or #10.00). Wait several
seconds for reading to stabilize. If adjustment is necessary, turn
screw labeled 4, 10 on the front panel of the meter (see diagram)
until the reading reaches 4.00 (or 10.00) exactly.
- RECALIBRATE
with #7.00 calibration fluid as step 1.
- Rinse
probe with fresh room temperature water.
- RECALIBRATE
with #4.00 (or 10.00) calibration fluid as step 3.
Continue
the calibration between both fluids. The two-point calibration is fully
complete when monitor will display both calibration fluids correctly
without any adjustment necessary.
Maintenance and Cleaning
Given proper care, the PINPOINT pH Monitor should
last a lifetime. Clean the probe tip gently every 3-4 weeks using a
SOFT TOOTHBRUSH with LONG BRISTLES. Push the probe tip down into the
wet bristles and rotate the probe 3-4 times. This will clean the inner
surfaces of the probe as well as the sensing glass and reference junctions.
No other cleaners are necessary or recommended. The LCD glass should
be cleaned occasionally with a non-abrasive glass cleaner and a soft
cloth. Replacement of the probe is necessary to maintain performance.
The probe should be discarded and replaced when it can no longer be
calibrated with 2 different calibration fluids. The useful life of a
PINPOINT pH Probe is approximately 18 months of continuous
duty.
Important Points to Remember
- PINPOINT
pH Monitor has been designed as a continuous monitor. However,
if you wish to activate the unit ON and OFF as needed, this will
lengthen the battery life from months to years.
- PINPOINT
pH meter is NOT waterproof and must be operated on a dry surface.
Liquid contact with the printed circuit board may cause corrosion
and void warranty.
- The
clear plastic cap must be removed from the tip of the probe so that
pH values can be measured. A small amount of storage fluid will
be expelled; this is normal.
- There
may be some white salt (potassium chloride crystals) residue around
the clear plastic cap. This is normal and can be washed off with
water.
- Keep
the sensing surface of the probe WET at all times. If the probe
is to be transported or stored, the plastic cap must be filled with
storage solution (4.00 calibration fluid + potassium chloride crystals)
or 4.00 calibration fluid prior to being installed onto the probe.
- Probe
should be inserted about 1 inch into the liquid to be measured.
Probe may be totally submerged if desired.
- If
several probes are used (i.e., pH and ORP, several pH, etc.) space
the probes 3-4 inches apart so that the probes will not react with
each other and yield erroneous readings.
- Clean
the sensing glass and reference junctions of the probe every few
weeks by using only a wet toothbrush.
- Replace
the probe every 18 months for optimum performance.
- Check
the calibration monthly to verify your pH readings.
- If
you note a pH reading on the display that you would like to verify
as correct. Place the probe into 2 different calibration fluids
(e.g. 7.00 & 10.00) to verify that it can read the 2 fluids
correctly. Recalibrate the meter if either, or both, of the 2 fluids
are displayed incorrectly.
- Do
not allow air bubbles to accumulate under a vertically installed
electrode.
|